Koristimo kolačiće da poboljšamo iskustvo na web lokaciji i naše preporuke.
Za više informacija, pročitajte našu Politiku kolačića.
Prihvati sve kolačiće
Podešavanja kolačića
Fuse Protection against the Regenerative Circuit Internal Commutation Fault, Hidaia Mahmood Alassouli
en
Knjige
Hidaia Mahmood Alassouli

Fuse Protection against the Regenerative Circuit Internal Commutation Fault

Current-limiting fuses are widely used to protect the thyristors in dc drive systems. In the event of the commutation failure when regenerating (inverting), the fuses need to interrupt in loop supplied by the ac and dc voltages acting in series which is the most difficult case for protection by fuse.

In this paper, a detailed study of the complete interruption process has been investigated by modeling of arcing process of the fuse. The effect varying the motor time constant, supply impedance, number of fuses used to clear the fault and dc machine rating to the total response for fuses protecting against the regenerative circuit internal commutation fault has been studied. The model of 200A fuse is employed in this study and fuses in series with the semiconductor devices (F1) and fuses in ac line (F2) are both considered.
više
26 štampanih stranica
Vlasnik autorskih prava
Bookwire
Prvi put objavljeno
2021
Godina izdavanja
2021
Da li već pročitali? Kakvo je vaše mišljenje?
👍👎